Self-Bunded DEF Tanks for AdBlue®

Every SCR-equipped vehicle in your fleet needs AdBlue® to operate. Storing and dispensing it correctly is not optional – contamination from moisture, heat, or the wrong materials will degrade the AdBlue® and damage the SCR system it is meant to protect.

Self-Bunded DEF Tanks for AdBlue® are purpose-built for bulk AdBlue® storage and dispensing. Australian-made, plug and play, and delivered ready to commission – double poly walls provide built-in 110% secondary containment, protecting your AdBlue® and your site from spills.

SELF-BUNDED DEF TANK SOLUTIONS FOR ADBLUE®

Browse Our Range of Self-Bunded DEF Tanks for AdBlue ®

Three series across five capacities. All share the same self-bunded double-wall construction, 110% bund capacity, and plug-and-play setup. The difference is in the power source, pump type, and management capability. 

Self-Bunded AdBlue DEF Tank

Self-Bunded DEF/AdBlue Tank 240V – Depot Range

Capacity:

2,300L / 3,300L / 5,000L / 7,000L / 10,000L

Self-Bunded AdBlue DEF Tank

Self-Bunded DEF/AdBlue Tank 12V – Depot Range

Capacity:

2,300L / 3,300L / 5,000L / 7,000L / 10,000L

Self-Bunded DEF Tank 240V – Submersible Range

Self-Bunded DEF/AdBlue Tank 240V – Submersible Range

Capacity:

2,300L / 3,300L / 5,000L / 7,000L / 10,000L

Self-Bunded DEF Tank 240V – Terminal Range

Self-Bunded DEF/AdBlue Tank 240V – Terminal Range

Capacity:

2,300L / 3,300L / 5,000L / 7,000L / 10,000L

WHICH SERIES SUITS YOUR OPERATION?

Depot,Terminal,or Submersible - Choosing the Right Series

All three series share the same self-bunded double-wall construction, 110% bund capacity, standard safety inclusions, and plug-and-play setup. The difference is in power source, pump type, hose configuration, and whether you need fuel management accountability.

The Depot series is the standard choice for transport operators and fleet sites that need reliable bulk AdBlue® storage and dispensing without fuel management overhead. Available in 12V (Piusi AdBlue® pump, 5m hose) and 240V configurations. The 12V option suits sites without mains power or setups where the pump draws from a vehicle battery; the 240V suits fixed depots with mains access. 

Ideal for: transport depots, farming operations, smaller fleet sites, and any application where a straightforward fill-and-dispense setup is sufficient.

The Terminal series adds the 120-user fuel management system to the Depot configuration. Individual users require a key to activate the pump; the system logs each dispensing transaction against the user, giving you a complete, auditable record of AdBlue® consumption across your fleet. An 8-metre retractable hose reel replaces the 5-metre hose.

Ideal for: larger transport fleets, mining operations, council depots, and any site where AdBlue® consumption needs to be tracked by vehicle or operator. Suited to multi-user environments where accountability and waste prevention are a priority.

The Submersible series replaces the external Piusi pump with a Calpeda submersible pump (standard) or Franklin submersible pump (option) mounted inside the tank. The discharge terminates within the cabinet at a 25mm (1-inch) outlet, which connects to a remote bowser or dispensing point. This configuration is specifically suited to service stations, public AdBlue® dispensing points, and any site where the storage unit needs to be located away from the dispensing point.

Ideal for: service station forecourts, roadside AdBlue® dispensing points, and any installation where the pump and storage are separated from the point of dispensing.

Highest Quality and Standards

Every DEF tank bunded station for AdBlue® is Australian-made, plug and play ready, and engineered to protect your AdBlue® from contamination, temperature damage, and spills.

ISO 9001 Quality Management

Manufacturer holds ISO 9001 certification – the international standard for quality management systems.

Australian Made

Designed, engineered, and manufactured right here in Australia, built for our climate and our conditions.

AS/NZS 4766 Certified

Independently certified to AS/NZS 4766:2020 for polyethylene storage tanks.

5 Year Warranty

Every DEF tank bunded station for AdBlue® carries a 5-year manufacturer’s warranty on the tank.

Why Choose Self-Bunded DEF Tanks for AdBlue®

Self-Bunded - Tank Within a Tank

Double poly walls with 110% bund capacity built in. No separate bund structure required. Any spill or leak is contained within the unit – protecting your site, your AdBlue®, and your compliance obligations. 

Stainless Steel Drybreak Fill Fitting

The 50mm (2-inch) stainless steel drybreak fill fitting prevents contamination during the fill process – a critical protection point given AdBlue®’s sensitivity to impurities.

Plug and Play - Ready to Commission

Every unit arrives factory-fitted: pump, digital tank volume measurement, overfill protection, alarms, cabinet, hose, and nozzle all installed. Commission on-site, not in a workshop.

Optional Fuel Management - 120 Users

The Terminal series adds a 120-user fuel management system as standard – the same accountability capability as Polymaster’s diesel Quantum series, applied to AdBlue® operations.

STANDARD INCLUSIONS ACROSS THE RANGE

What Comes With Every DEF Tank Bunded Station for AdBlue®

Every unit in the BMDS range ships with a comprehensive set of standard inclusions:  

  • The tank and bund: self-bunded double poly wall construction with 110% bund capacity, mechanical overfill protection, earth rod, stainless steel drybreak fill fitting (50mm, 2-inch), and digital tank volume measurement.  
  • The control and safety equipment: power control panel with emergency stop, auto timeout (10 minutes), high and low level audible alarms, bund alarm, lockable cabinet.  
  • The dispensing equipment: Piusi or Calpeda pump (depending on series), hose with auto-shutoff nozzle and holster, digital flow meter (Depot and Terminal series), and digital or pulse meter (series dependent).  
  • Optional add-ons available across the range include an ATG probe tube, tank lifting lugs, and an 8-metre retractable hose reel (standard on Terminal, optional on Depot).  

INSTALLATIONO VERVIEW

Installing Your DEF Tank Bunded Station for AdBlue®

DEF tank bunded stations for AdBlue® are plug-and-play units – pump, fittings, controls, and cabinet all factory-installed. Installation involves site preparation, positioning, electrical connection, and commissioning. Download the AdBlue® Bunded Station Installation Guide for full specifications.

Select a firm, level surface capable of bearing the loaded weight of the unit. Position to allow access for the AdBlue® delivery vehicle to reach the stainless steel drybreak fill fitting. Ensure adequate clearance around the cabinet for maintenance access.

The pump and control panel require a licensed electrician to complete the electrical connection. The Depot 12V option connects to a 12V vehicle battery; the 240V Depot, Terminal, and Submersible configurations require a mains electrical connection. All wiring must be completed by a licensed electrician.

Commission the pump per the Piusi or Calpeda commissioning instructions supplied with the unit. Test flow rate, auto-shutoff nozzle, and overfill protection. Test the high/low level alarms and bund alarm for correct operation.

Program the management key and distribute user keys to authorised operators. Test each key for access authorisation. Review the digital display and confirm transaction logging is active before commissioning.

Arrange AdBlue® delivery via an approved AdBlue® supplier using the drybreak fill fitting. Do not allow any non-AdBlue® material, water, or incompatible liquids to enter the tank. Confirm the digital tank volume reading after the first fill.

DEF tank bunded stations for AdBlue® must be installed in accordance with the AdBlue® Bunded Station Installation Guide. All electrical connections must be completed by a licensed electrician. AdBlue® is sensitive to contamination – only fill from an approved AdBlue® supply source using the drybreak fitting provided.

DELIVERY AND DISTRIBUTION

Delivery Across Victoria, South Australia, New South Wales, and Queensland

Preparing Your Site

Truck and trailer clearance required is 19 metres long, 5 metres high, and 3.5 metres wide. Check for low branches or powerlines on your access route and ensure your gate and entrance can accommodate a 19m truck and trailer. A flat, clear area of at least 5 metres by 5 metres is required for unloading. Our logistics team will contact you approximately seven days before delivery to confirm your address and access requirements.

Explore Other Tanks

Single-walled AdBlue round tank
Single-Walled Round Tanks
Single-Walled Slimline Tanks
Scroll to Top